Types of Fire Alarm Cables

A fireplace alarm cable isn’t a “one-size-fits-all” product. Actually, there are lots of types of such cables on industry. To muddle the problem much more, the fireplace alarm cable somebody uses and recommends might not be also the correct one for the situation. The groups and subcategories of those cables are plenty of and varied.

How do we go through the numerous options to look for the one that’s most appropriate for your specific needs? The most crucial question to inquire about on your own is what sort of building structure you are searching for the cable for. For example, a higher-rise building will need a different sort of fire alarm cable than other structures will. That is because in case of an evacuation, a higher-rise is outfitted having a very specific type of fire security alarm, one that’s customized to take into consideration all sorts of hazards the occupants of this building may encounter.

Among the primary groups of cable you might encounter in your search is really a power limited fire alarm cable. The enclosed tracks or tubes by which this kind of cable operates is mandated by legal stipulations. For instance, this sort of cable is illegitimate from extending greater than 10 ft outdoors of the enclosure.

Breaking power limited cables lower even more, you will find three subcategories available being used today. The very first could well be fire power limited cable, or FPL cable. This kind of cable spans the largest selection of usages, but there are several limitations put on it. Particularly, FPL cable can’t be utilized in vents, ducts, or any other air passageways, a stipulation that top-rise proprietors should be aware.

The 2nd subcategory of limited fire alarm cable is fire power limited plenum or FPLP cable for brief. This kind of cable was created particularly to be used in mid-air passageways between rooms on the floor and it is generally present in high-rise apartment structures. Finally, fire power limited riser or FPLR runs vertically between your floors of the high-rise structure.

Another major cable classification is non-power limited cable, that has two primary subcategories. The very first of those subcategories is non-power limited fire alarm cable or NPLF. For general use, NPLF is appropriate for many types of installation. The 2nd subcategory of non-power limited cable is non-power limited fire protective (NPLFP) cable, that is particularly tailored to air passageway usage. Driving lower an amount much deeper, these FPLPs could be further indexed by their insulation material (i.e., fire and smoke retardant PVC or fluoropolymer based). Another classification in this particular group of fire alarm cable is “limited combustible.” This designation attests the FPLP matches the rules for limited combustibility as established through the U.S. through the National Fire Protection Association.

Your final word of caution about unshielded fire alarm cables, which may be either power limited or NPLF. Although they may be utilized on the alarm itself for connecting the alarm towards the warning system, they may be broken in case of a fireplace.